Mai-Liao Power Plant has 3 sets of 600MW super-critical coal fired power units, using the Best Available Control Technology of environmental protection equipment, the flue gas after the treatment of Selective Catalytic Reduction (SCR), Electric Precipitator (EP) and Flue Gas Desulfurization (FGD), the concentration of SOx、NOx and Total Suspended Particles (TSP) from the coal fired flue gas is almost near the natural fired gas power units. Mai-Liao Power Plant is a clean coal fired power units, the flue gas emission standard is not only much lower than the national standard but also the restricted regulation of Yun Lin County.
Standard | SOx (ppm) |
NOx (ppm) |
TSP (mg/Nm3) |
Remarks |
---|---|---|---|---|
Yun Lin County Restricted Regulation |
25 | 46 | 15 | The Notice of Yun Lin County dated 10/04/17 "The air pollution emission standard of Yun Lin County for power generation", for the existed since 04/04/2017. |
Taiwan National Standard |
60 | 70 | 20 | The Notice of restricted regulation for air emission of EPA dated 12/01/2014, for the existed since 12/01/2016. |
![]() |
![]() |
|
FGD:Flue gas desulfurization |
![]() |
|
EP: Electrostatic Precipitator |
![]() |
|
SCR:Selective Catalytic Reduction |
![]() |
|
Low NOx Burner |